Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: TC-MDP-0626-00483

Parcel: 141462020


Addresses:

7361 S KELLER LN

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Roof Nailing 

Date Description Inspector Results Comments
07/31/2026 COT - RSBU - Roof Nailing  Re-inspection required 07/31/2026
HTT5 not set at SW11 inside garage, missing LUS26 hanger at FG6 small girder in garage as well as 2x4 ledger at girder per elevation B plan. Missing A34 clips at stringers on stairs and landings. Add anchor bolts at marked locations. No truss calcs provided. NOTE: Stopped inspection, more items may be noted. Next inspector needs to walk 2nd floor and roof.
08/03/2026 COT - RSBU - Roof Nailing  Not Ready 08/03/2026
Not ready. See prior notes and missing SW9 upstairs to southeast corner.
08/04/2026 COT - RSBU - Roof Nailing  Passed 08/04/2026
Corrections made.