Permit: TC-MDP-0626-00441

Parcel: 141461890


Addresses:

9601 E WYNALDA DR

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Interior Shear BracingĀ 

Date Description Inspector Results Comments
09/08/2026 COT - RSBU - Interior Shear BracingĀ  Re-inspection required 9-8-26 fasteners need to be no less then 3/8" from edge [throughout] fastener should not penetrate drywall more than eighth of an inch (1/8") also fasteners should be placed at 12 inches on center [throughout]. Please re-walk before calling it in. Shearwall was walked and is okay
09/09/2026 COT - RSBU - Interior Shear BracingĀ  Passed 9-9-26 all items have been corrected