Inspection Status: Re-inspection required

Inspection History: COT - RSME - Mechanical Final 

Date Description Inspector Results Comments
07/02/2026 COT - RSME - Mechanical Final  Re-inspection required 07/02/2026
House requires address 4" numbers visible from street, cut cleanout flush to grade at drive, living room breakers needs AFCI type, r3 insulate hot water line at water heater, paint exposed plastic pipes, completely install range and water hammer arrestor at dish washer line. Could not verify mechanical on roof.
07/20/2026 COT - RSME - Mechanical Final  Canceled 7-20-26: canceled by contractor.
07/31/2026 COT - RSME - Mechanical Final  Passed 07/31/2026
All corrections made.