Permit: TC-MDP-0625-00357

Parcel: 141461410


Addresses:

9645 E MEOLA DR

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Roof NailingĀ 

Date Description Inspector Results Comments
04/10/2026 COT - RSBU - Roof NailingĀ  Re-inspection required 04/10/2026
STHD10 holdown at interior SW13 misplaced on concrete - requires HTT5 equivalent. Front garage SW13 and rear SW11 requires washer plates and add anchor bolt as marked, add anchor bolts at other marked locations, add roof nails to loose panels as marked upstairs on floor at front and rear.
04/14/2026 COT - RSBU - Roof NailingĀ  Passed 04/14/2026
All corrections made to prior inspection.