Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
Permit Number - TC-MDP-0625-00352
Inspection Description - COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
Inspection Status - Re-inspection required
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/24/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Re-inspection required | 10.24.2025 Add nails to south SW9 near great room as marked, add 2x4 diagonal bracing 48" per detail SD2-201 at front garage area, add steel washer plates to anchor bolts at interior shear wall per SW13 schedule, ladder blocking needs to be 2x6 at 24" o.c. per SD3-307 if using option B or C and verify A35 clip after roof is loaded, add double stud as marked on south garage wall continuous to girder roof truss. |
|
| 10/28/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Partial Pass | 10/28/25 partial pass, check washer plates installed at sw11 by back porch at intermediate | |
| 11/12/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Re-inspection required | 11/12/25: over notched non-bearing studs must be corrected or replaced, damaged sheathing on electrical wiring must be addressed at main circuits coming in at south east corner, remove nm cable away from gusset plates, 4-gang boxes require blocking, exterior receptacles should be 12AWG cable for 20AMP circuit, seal all penetrations through vapor barrier at pantry, seal all penetrations through top plate at first floor, seal all plenum boxes at end cap, torn flex must be fixed, Boca plates required throughout. STOPPED INSPECTION. MORE ITEMS MAY BE ADDED (second floor was not walked). | |
| 11/14/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | 11.14.2025 All corrections made to 11.12.2025 inspection and foamed and added steel screws to upstairs fan boxes. Added stud shoe to notched stud. |