Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Parcel: 141460010


Addresses:

7310 S DEMPSEY AV


Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Roof Nailing 

Permit Number - TC-MDP-0625-00350

Inspection Description - COT - RSBU - Roof Nailing 

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
08/26/2025 COT - RSBU - Roof Nailing  Re-inspection required Missing 3" washer plates at needed shear walls, sw13 anchor bolts should be 17"oc, replace or sister 2 damaged studs downstairs, 1 damaged stud upstairs. Siding at 2nd floor north wall falling off, missing anchor bolts at marked areas, missing h25 clip at marked areas, nailing at detail 306 2nd floor not per plan, missing nails at supports in garage, missing nails at edge shear wall south end of house, loose roofing at marked areas
08/27/2025 COT - RSBU - Roof Nailing  Re-inspection required Missing studs underneath all girder trusses along with h25's. Nailing at ledger rear porch not per schedule. Provide plans whether or not it's a re inspection. 8/27/2025
08/28/2025 COT - RSBU - Roof Nailing  Not Ready Trades working in dwelling without the approval of the inspection. Materials are all over the floors. Provide a cleaning working environment prior to inspection. Provide plans on site. 8/28/2025
08/29/2025 COT - RSBU - Roof Nailing  Passed