Inspection History Details
Inspection Status: Passed
Inspection History: COT - RSPL - Plumbing Final
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/20/2026 | COT - RSPL - Plumbing Final | Passed | 01/20/2026 All corrections made to 12/15/25 inspection. |
|
| 12/15/2025 | COT - RSPL - Plumbing Final | Re-inspection required | 12-15-25: unit 2-missing stove, anti-tip device, paint exterior plastic, arch fault breakers required required for living room, connect condensation line with a 90Degree elbow at water heater closet, missing R3 insulation on hot leg of water heater, seal water closet. Unit1-missing stove, anti tip device, connect condensation line with a 90 degree elbow, paint all exterior plastic, add R3 insulation to hot leg of water heater, archfault breakers required required for living room required, weather resistant gfci's required on exterior both units. |