Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: TC-MDP-0625-00341

Parcel: 138192410


Addresses:

378 W ELVIRA RD

Inspection Status: Passed

Inspection History: RSBU - Building Final 

Date Description Inspector Results Comments
01/20/2026 RSBU - Building Final  Passed 01/20/2026
All corrections made to 12/15/25 inspection.
12/15/2025 RSBU - Building Final  Re-inspection required 12-15-25: unit 2-missing stove, anti-tip device, paint exterior plastic, arch fault breakers required required for living room, connect condensation line with a 90Degree elbow at water heater closet, missing R3 insulation on hot leg of water heater, seal water closet.
Unit1-missing stove, anti tip device, connect condensation line with a 90 degree elbow, paint all exterior plastic, add R3 insulation to hot leg of water heater, archfault breakers required required for living room required, weather resistant gfci's required on exterior both units.