09/18/2024 COT - RSBU - Exterior Clips/Sheathing  Re-inspection required Add 2 studs in garage area east wall. Plans call for 2x4 every 12" o.c. Add anchor bolts per shear wall schedule, break in plates, and for every third masa leg up. Add more nails to exterior walls 2nd floor. Missing bracing at truss A04. 9/18/2024
10/11/2024 COT - RSBU - Exterior Clips/Sheathing  Re-inspection required Per previous notes. 10/11/2024
10/23/2024 COT - RSBU - Exterior Clips/Sheathing  Re-inspection required 10-23-24, provide truss bracing per previous inspection notes.
10/24/2024 COT - RSBU - Exterior Clips/Sheathing  Passed 10-24-24, items noted from inspection 9-18 have been corrected.Okay to proceed with construction.