Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.

Permit Number - TC-MDP-0624-00748

Inspection Description - COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
11/18/2024 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Re-inspection required Partial pass. Provide 4" at san tee. DWV not on test. 11/18/2024
COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Re-inspection required Partial pass. Provide 4" at san tee. DWV not on test. 11/18/2024

11/19/24 vent needs to be 10' away from the fresh air intake. Seal penetrations throughout, straps required throughout on pvc, DWV not on test. Trap for shower needs strap.
11/20/2024 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Canceled 11-20-24, cancelled by contractor.
11/21/2024 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Re-inspection required (with fee) 11-21-24, add fire foam to seal penetration at garage & laundry room (areas marked), lower thermostat height to a maximum height of 54 inches, seal tears to upstairs flex near attic chute with tape (not fire foam), dwv leaking at upstairs master bathroom.
COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Scheduled