Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Roof Nailing
Permit Number - TC-MDP-0624-00748
Inspection Description - COT - RSBU - Roof Nailing
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/18/2024 | COT - RSBU - Roof Nailing | Re-inspection required | Add 2 studs in garage area east wall. Plans call for 2x4 every 12" o.c. Add anchor bolts per shear wall schedule, break in plates, and for every third masa leg up. Add more nails to exterior walls 2nd floor. Missing bracing at truss A04. 9/18/2024 | |
10/11/2024 | COT - RSBU - Roof Nailing | Passed |