Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Permit Number - TC-MDP-0624-00740

Inspection Description - COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
10/15/2024 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required 10/15/24: missing anchor bolt at bottom plate south east corner. Rsp clips missing on west side and east side of home. Bearing points for girders need to have studs installed to support both front and back of home. H25 clip missing on west side of home at trust in bathroom. more items can be added.
10/21/2024 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed 10/21/24: Anchor bolts have been installed, RSP Clips are installed where missing, studs have been added at girders, and H2.5 clips have been installed where missing. Okay to proceed with rough-in of M, P, AND E.