Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Roof Nailing
Permit Number - TC-MDP-0624-00738
Inspection Description - COT - RSBU - Roof Nailing
Inspection Status - Re-inspection required
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/25/2024 | COT - RSBU - Roof Nailing | Re-inspection required | Missing rsp4's east wall, add anchor bolt where marked (east wall), shot pins missing throughout interior framing (one shot pin shall be installed at 6 inches from each end of each sill plate.)Missing t-15 on truss calculations-verify truss calcs.,add nails to straps on north end of building. | |
| 10/31/2024 | COT - RSBU - Roof Nailing | Passed | 10-31-24, roof nailing approved. |