Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior Clips/Sheathing
Permit Number - TC-MDP-0624-00719
Inspection Description - COT - RSBU - Exterior Clips/Sheathing
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/03/2024 | COT - RSBU - Exterior Clips/Sheathing | Re-inspection required | 10/3/24:Blocking required at soffits/drop ceiling, anchor bolts required 12" from edge of sill plate, sill plate larger than 12" requires 2 anchor bolts, hangers missing at entry, SDWS Timber screws required at entry 2x6 ledger, shear wall nailing penetrating more than 1/8", hangers required at back porch, properly fasten anchor bolts, rsp4 required every other stud, 2x4 flat blocking not per detail 2F, A35 required at each stringer at stairs, double top plate called at knee wall under stairs, STOPPED INSPECTION MORE ITEMS MAY BE ADDED. | |
10/07/2024 | COT - RSBU - Exterior Clips/Sheathing | Re-inspection required | Per previous notes. Call in when workers are not in house. 10/7/2024 | |
10/14/2024 | COT - RSBU - Exterior Clips/Sheathing | Re-inspection required | Add anchor bolt to front porch area due to being out of center third. Add anchor to shear wall at great room area. Add double studs and blocking in floor space underneath girder truss in garage area. Add h25 clip 2nd floor north wall. Add more nails to exterior and interior marked areas bottom plates. Secure wall at landing second floor. 10/14/2024 | |
10/16/2024 | COT - RSBU - Exterior Clips/Sheathing | Re-inspection required | Per previous notes. 10/16/2024 | |
10/18/2024 | COT - RSBU - Exterior Clips/Sheathing | Re-inspection required (with fee) | 10/3/24:Blocking required at soffits/drop ceiling, anchor bolts required 12" from edge of sill plate, sill plate larger than 12" requires 2 anchor bolts, hangers missing at entry, SDWS Timber screws required at entry 2x6 ledger, shear wall nailing penetrating more than 1/8", hangers required at back porch, properly fasten anchor bolts, rsp4 required every other stud, 2x4 flat blocking not per detail 2F, A35 required at each stringer at stairs, double top plate called at knee wall under stairs, STOPPED INSPECTION MORE ITEMS MAY BE ADDED. Per previous notes. Call in when workers are not in house. 10/7/2024 Add anchor bolt to front porch area due to being out of center third. Add anchor to shear wall at great room area. Add double studs and blocking in floor space underneath girder truss in garage area. Add h25 clip 2nd floor north wall. Add more nails to exterior and interior marked areas bottom plates. Secure wall at landing second floor. 10/14/2024 Per previous notes. 10/16/2024 10/18/24: properly secure anchor bolts at entry column, nosing at stairs tread greater than 1 1/4", properly secure at landing 2nd floor. Re-inspection required with fee |
|
10/22/2024 | COT - RSBU - Exterior Clips/Sheathing | Passed |