Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior Clips/Sheathing 

Permit Number - TC-MDP-0624-00719

Inspection Description - COT - RSBU - Exterior Clips/Sheathing 

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
10/03/2024 COT - RSBU - Exterior Clips/Sheathing  Re-inspection required 10/3/24:Blocking required at soffits/drop ceiling, anchor bolts required 12" from edge of sill plate, sill plate larger than 12" requires 2 anchor bolts, hangers missing at entry, SDWS Timber screws required at entry 2x6 ledger, shear wall nailing penetrating more than 1/8", hangers required at back porch, properly fasten anchor bolts, rsp4 required every other stud, 2x4 flat blocking not per detail 2F, A35 required at each stringer at stairs, double top plate called at knee wall under stairs, STOPPED INSPECTION MORE ITEMS MAY BE ADDED.
10/07/2024 COT - RSBU - Exterior Clips/Sheathing  Re-inspection required Per previous notes. Call in when workers are not in house. 10/7/2024
10/14/2024 COT - RSBU - Exterior Clips/Sheathing  Re-inspection required Add anchor bolt to front porch area due to being out of center third. Add anchor to shear wall at great room area. Add double studs and blocking in floor space underneath girder truss in garage area. Add h25 clip 2nd floor north wall. Add more nails to exterior and interior marked areas bottom plates. Secure wall at landing second floor. 10/14/2024
10/16/2024 COT - RSBU - Exterior Clips/Sheathing  Re-inspection required Per previous notes. 10/16/2024
10/18/2024 COT - RSBU - Exterior Clips/Sheathing  Re-inspection required (with fee) 10/3/24:Blocking required at soffits/drop ceiling, anchor bolts required 12" from edge of sill plate, sill plate larger than 12" requires 2 anchor bolts, hangers missing at entry, SDWS Timber screws required at entry 2x6 ledger, shear wall nailing penetrating more than 1/8", hangers required at back porch, properly fasten anchor bolts, rsp4 required every other stud, 2x4 flat blocking not per detail 2F, A35 required at each stringer at stairs, double top plate called at knee wall under stairs, STOPPED INSPECTION MORE ITEMS MAY BE ADDED.

Per previous notes. Call in when workers are not in house. 10/7/2024

Add anchor bolt to front porch area due to being out of center third. Add anchor to shear wall at great room area. Add double studs and blocking in floor space underneath girder truss in garage area. Add h25 clip 2nd floor north wall. Add more nails to exterior and interior marked areas bottom plates. Secure wall at landing second floor. 10/14/2024

Per previous notes. 10/16/2024

10/18/24: properly secure anchor bolts at entry column, nosing at stairs tread greater than 1 1/4", properly secure at landing 2nd floor. Re-inspection required with fee
10/22/2024 COT - RSBU - Exterior Clips/Sheathing  Passed