Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Roof Nailing
Permit Number - TC-MDP-0624-00719
Inspection Description - COT - RSBU - Roof Nailing
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/03/2024 | COT - RSBU - Roof Nailing | Re-inspection required | 10/3/24:Blocking required at soffits/drop ceiling, anchor bolts required 12" from edge of sill plate, sill plate larger than 12" requires 2 anchor bolts, hangers missing at entry, SDWS Timber screws required at entry 2x6 ledger, shear wall nailing penetrating more than 1/8", hangers required at back porch, properly fasten anchor bolts, rsp4 required every other stud, 2x4 flat blocking not per detail 2F, A35 required at each stringer at stairs, double top plate called at knee wall under stairs, STOPPED INSPECTION MORE ITEMS MAY BE ADDED. | |
10/07/2024 | COT - RSBU - Roof Nailing | Re-inspection required | Per previous notes. Call in when workers are not in house. 10/7/2024 | |
10/14/2024 | COT - RSBU - Roof Nailing | Passed | Approved. 10/14/2024 |