Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Roof Nailing 

Permit Number - TC-MDP-0624-00719

Inspection Description - COT - RSBU - Roof Nailing 

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
10/03/2024 COT - RSBU - Roof Nailing  Re-inspection required 10/3/24:Blocking required at soffits/drop ceiling, anchor bolts required 12" from edge of sill plate, sill plate larger than 12" requires 2 anchor bolts, hangers missing at entry, SDWS Timber screws required at entry 2x6 ledger, shear wall nailing penetrating more than 1/8", hangers required at back porch, properly fasten anchor bolts, rsp4 required every other stud, 2x4 flat blocking not per detail 2F, A35 required at each stringer at stairs, double top plate called at knee wall under stairs, STOPPED INSPECTION MORE ITEMS MAY BE ADDED.
10/07/2024 COT - RSBU - Roof Nailing  Re-inspection required Per previous notes. Call in when workers are not in house. 10/7/2024
10/14/2024 COT - RSBU - Roof Nailing  Passed Approved. 10/14/2024