Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Excavation/Rebar/Zoning
Permit Number - TC-MDP-0624-00715
Inspection Description - COT - RSBU - Excavation/Rebar/Zoning
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/22/2024 | COT - RSBU - Excavation/Rebar/Zoning | Re-inspection required | 10/22/24: tendons with damaged sheathing must be repaired, #4 dowel at holdown 30"x30" required at garage. Site plan not provided to verify setbacks. | |
10/24/2024 | COT - RSBU - Excavation/Rebar/Zoning | Passed | 10-24-24, verified setbacks together with items from previous inspection corrected. |