Date Description Inspector Results Comments
12/10/2024 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Re-inspection required 12-10-24, missing ufer at panel-install 2 ground rods minimum 6 feet apart, all h25's must be nailed at time of inspection, pancake box at garage coach light is rated for 6 cubic inches. There are 2 4/ awg wires and is overfilled.
12/16/2024 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed 12-16-24, intermediate inspection approved plans. Ok to continue with construction.