Inspection Status: Partial Pass

Inspection History: COT - RSBU - Exterior Clips/Sheathing 

Permit Number - TC-MDP-0624-00691

Inspection Description - COT - RSBU - Exterior Clips/Sheathing 

Inspection Status - Partial Pass

Date Description Inspector Results Comments
10/16/2024 COT - RSBU - Exterior Clips/Sheathing  Partial Pass Partial pass. Missing hangers at jack trusses in garage. Loose shear wall at garage perimeter sheathing. Htt4's are not nailed or set in place. Missing anchor bolts and nuts at marked areas. Add shot pins at interior marked areas. Missing h25 at hallway bathroom truss area. 10/16/2024
10/18/2024 COT - RSBU - Exterior Clips/Sheathing  Re-inspection required Partial pass. Missing hangers at jack trusses in garage. Loose shear wall at garage perimeter sheathing. Htt4's are not nailed or set in place. Missing anchor bolts and nuts at marked areas. Add shot pins at interior marked areas. Missing h25 at hallway bathroom truss area. 10/16/2024
10/18/24: per previous notes
10/23/2024 COT - RSBU - Exterior Clips/Sheathing  Re-inspection required 10-23-24, per previous notes. Reinspection required.
10/29/2024 COT - RSBU - Exterior Clips/Sheathing  Passed 10-29-24, hangers not required per approved plans, all additional items requiring correction were taken care of. Okay to proceed with construction.