Inspection Status: Re-inspection required
Inspection History: RSBU - Building Final
| Date |
Description |
Inspector |
Results |
Comments |
| 04/01/2024 |
RSBU - Building Final |
|
Re-inspection required |
4/1/24: Cut clean-outs to grade and cap, exterior plastic piping must be coated for uv protection, YWL must be properly insulated and wrapped, kitchen requires 2 circuits. STOPPED INSPECTION MORE ITEMS MAY BE ADDED. |
| 04/03/2024 |
RSBU - Building Final |
|
Re-inspection required |
Receptacles installed in kitchen must be supplied by two separate branch circuits per E3901.3.2. |
| 04/05/2024 |
RSBU - Building Final |
|
Passed |
|