Inspection Status: Re-inspection required
Inspection History: RSBU - Building Final
Permit Number - TC-MDP-0623-01201
Inspection Description - RSBU - Building Final
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/01/2024 | RSBU - Building Final | Re-inspection required | 4/1/24: Cut clean-outs to grade and cap, exterior plastic piping must be coated for uv protection, YWL must be properly insulated and wrapped, kitchen requires 2 circuits. STOPPED INSPECTION MORE ITEMS MAY BE ADDED. | |
04/03/2024 | RSBU - Building Final | Re-inspection required | Receptacles installed in kitchen must be supplied by two separate branch circuits per E3901.3.2. | |
04/05/2024 | RSBU - Building Final | Passed |