Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior Clips/Sheathing 

Permit Number - TC-MDP-0623-01189

Inspection Description - COT - RSBU - Exterior Clips/Sheathing 

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
08/22/2023 COT - RSBU - Exterior Clips/Sheathing  Re-inspection required Missing anchors at shear walls, add more nails to sole plates.
08/23/2023 COT - RSBU - Exterior Clips/Sheathing  Partial Pass Partial pending truss repair towards front garage. 8/23/2023
09/25/2023 COT - RSBU - Exterior Clips/Sheathing  Re-inspection required Missing anchors at shear walls, add more nails to sole plates.

Partial pending truss repair towards front garage. 8/23/2023.
9/25/23: provide copy of truss repair, staple 2nd copy to the area of repair, send 3rd copy into portal.
12/06/2023 COT - RSBU - Exterior Clips/Sheathing  Passed