Permit: TC-MDP-0623-01163

Parcel: 11820019A


Addresses:

1205 S HERNDON AV

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Interior Shear Bracing 

Date Description Inspector Results Comments
08/01/2025 COT - RSBU - Interior Shear Bracing  Re-inspection required 8-1-25: add anchor to marked location, missing cross bracing at middle point of home-plans call for it every 25' o.c., missing truss calcs, add shot pins every 24" o.c. And within 6" at end of each plate-minimum of 2 shot pins per plate, add nails to exterior sheathing at marked locations where over penetrated -nails cannot be closer than 3/8" from edges/joints.
08/04/2025 COT - RSBU - Interior Shear Bracing  Not Ready 8-4-25: will inspect drywall when ready.
08/08/2025 COT - RSBU - Interior Shear Bracing  Not Ready
08/11/2025 COT - RSBU - Interior Shear Bracing  Not Applicable