Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/08/2025 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Re-inspection required | 8.8.2025 Missing interior non-loading stud between bedroom 1 and 2. Seal wall penetrations at NE and S walls, ducts need support straps, DWV not under test, seal top plate at dry vent near bathroom, thermostat needs sealed at top plate, need FHA plate at kitchen hood duct. Electrical panel shows 17 circuits and not per plan, plan shows 21 circuits. |
|
| 08/11/2025 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | Approved. Corrections were made. 8/11/2025 |