Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Passed
Inspection History: COT - RSEL - Electrical Underground
Permit Number - TC-MDP-0623-01157
Inspection Description - COT - RSEL - Electrical Underground
Inspection Status - Passed
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/14/2023 | COT - RSEL - Electrical Underground | Passed | Ufer ground is in place, forms are set with post-tension cables, subsoil is properly compacted, plumbing pipes are properly wrapped with foam, and all shear wall clips are in place. Underground electrical is in place for kitchen island. Okay to pour concrete for monolithic concrete slab. |