Inspection Status: Passed

Inspection History: COT - RSBU - Preslab  

Permit Number - TC-MDP-0623-01149

Inspection Description - COT - RSBU - Preslab  

Inspection Status - Passed

Date Description Inspector Results Comments
11/08/2023 COT - RSBU - Preslab   Passed Rebar reinforcement is in place per plans, post tension cabling is installed and properly supported off of ground, Ufer ground is in place and the proper length, underground electrical for kitchen island is properly installed, plumbing pipes are properly wrapped with styrofoam sheeting, and subsoil is properly compacted. Okay to pour concrete for slab on grade.