Inspection Status: Not Ready
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
| Date |
Description |
Inspector |
Results |
Comments |
| 01/03/2024 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Not Ready |
|
| 01/04/2024 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Canceled |
1/4/24: canceled per contractor |
| 01/09/2024 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Re-inspection required (with fee) |
Add nails to h2.5 clip at left side of garage, missing anchor bolts back left shear wall and Sthd hold down not nailed to shear wall. Engineer fix required, missing rsp4 clips top plate of second floor window right side of house. House has proceeded to intermediate and been lathed before passing intermediate. Re-inspection with fee required. |
| 01/11/2024 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Canceled |
Cancelled per Trent. |
| 01/12/2024 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Partial Pass |
Missing rsp4 clips top plate of second floor window right side of house. Check at intermediate. |
| 01/19/2024 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Passed |
|
| 11/21/2023 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Re-inspection required |
Sthd hold down left side of garage over spalled, add nails to h2.5 clip at left side of garage, Sthd hold down at front porch door misplaced. Add appropriate HTT hold down substitute, missing anchor bolts back left shear wall and Sthd hold down not nailed to shear wall. Add HTT substitute, missing rsp4 clips top plate of second floor window right side of house. |