Inspection History Details
Inspection Status: Re-inspection required
Inspection History: BULD - Electrical Clearance
Permit Number - TC-MDP-0623-01143
Inspection Description - BULD - Electrical Clearance
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/20/2023 | BULD - Electrical Clearance | Re-inspection required | GEC not connected to ufer, support 4-gang box at kitchen, open chase at kitchen pantry, complete wiring in second floor front of house at ceiling, add h2.5 clips to double GT at front of house. | |
11/27/2023 | BULD - Electrical Clearance | Re-inspection required | Missing GFCI temp. Outlet receptacle. | |
11/30/2023 | BULD - Electrical Clearance | Passed | 1/12/24 clerance resent |