Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Parcel: 141431160


Addresses:

7795 S VIA PERFECTA


Inspection Status: Passed

Inspection History: COT - RSBU - Exterior Clips/Sheathing 

Permit Number - TC-MDP-0623-01136

Inspection Description - COT - RSBU - Exterior Clips/Sheathing 

Inspection Status - Passed

Date Description Inspector Results Comments
01/09/2024 COT - RSBU - Exterior Clips/Sheathing  Passed
12/08/2023 COT - RSBU - Exterior Clips/Sheathing  Re-inspection required Add studs to fully support load of GLB in kitchen left side of house, add anchor bolt to front of garage, anchor bolt right side of house, add anchor bolt left side of house, add nails to sole plate in second floor, missing plans and truss calcs.
12/13/2023 COT - RSBU - Exterior Clips/Sheathing  Re-inspection required Add studs to fully support load of GLB in kitchen left side of house, add anchor bolt to front of garage, anchor bolt right side of house, add anchor bolt left side of house, missing plans and truss calcs. Stopped inspection. Walk house before calling for inspection.
12/21/2023 COT - RSBU - Exterior Clips/Sheathing  Re-inspection required (with fee) Front porch missing hangers per plans, add studs at each end of 4x6 foyer beam to fully bear load, beam at kitchen missing second CS16 strap between beam and top plate, master suite missing hangers, shim all trimmers not making contact with headers, add shot pin at master bedroom, THA422 hangers at foyer not fully installed/nailed, second floor missing hangers, missing nails at sole plate in second floor, no truss calcs present.