Inspection History Details
Inspection Status: Re-inspection required
Inspection History: BULD - Electrical Clearance
Permit Number - TC-MDP-0623-01135
Inspection Description - BULD - Electrical Clearance
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/08/2023 | BULD - Electrical Clearance | Re-inspection required | Electrical not per plans, pex lines within 12” of can lights must be insulated, gas not under test, complete wiring in kitchen and at service panel, missing clean out at kitchen pantry, dwv and showers/tubs not under test, support 4-gang boxes in second floor, complete wiring second floor room at front of house, support duct registers on 3 sides second floor, complete wiring in loft, complete wiring for receptacle in laundry room, complete wiring in master bedroom, electrical clearance not ready, electrical and plumbing not per plans. | |
12/29/2023 | BULD - Electrical Clearance | Passed | 2/23/24 clearance resent |