Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior Clips/Sheathing
Permit Number - TC-MDP-0623-01121
Inspection Description - COT - RSBU - Exterior Clips/Sheathing
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/28/2023 | COT - RSBU - Exterior Clips/Sheathing | Re-inspection required | Vertical beam at front porch calls for 6x6, no horizontal beams at front porch. Calls for 2-2x6 headers. Foundation and studs not built to support such load, add king stud to each side of flex room window, flex room requires 2-2x8 headers, all 4x6 headers must be supported by 2-2x6 studs, missing king stud at master bedroom, Fireblock master shower, missing anchor bolts at perimeter, missing rsp4 at back of house, add nails to massa clips, requesting structural engineering for front porch, revise plans to show work done, provide truss calcs. | |
08/29/2023 | COT - RSBU - Exterior Clips/Sheathing | Passed | Corrections have been made. 8/29/2023 |