Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
Permit Number - TC-MDP-0623-01121
Inspection Description - COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
Inspection Status - Re-inspection required
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/28/2023 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Re-inspection required | Vertical beam at front porch calls for 6x6, no horizontal beams at front porch. Calls for 2-2x6 headers. Foundation and studs not built to support such load, add king stud to each side of flex room window, flex room requires 2-2x8 headers, all 4x6 headers must be supported by 2-2x6 studs, missing king stud at master bedroom, Fireblock master shower, missing anchor bolts at perimeter, missing rsp4 at back of house, add nails to massa clips, requesting structural engineering for front porch, revise plans to show work done, provide truss calcs. | |
| 08/29/2023 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | Corrections have been made. 8/29/2023 |