Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Passed
Inspection History: COT - RSBU - Preslab
Permit Number - TC-MDP-0524-00687
Inspection Description - COT - RSBU - Preslab
Inspection Status - Passed
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/28/2024 | COT - RSBU - Preslab | Passed | Forms are set, masa clips are installed 4' apart, shear wall Simpson straps are installed per plan, underground plumbing is properly wrapped with foam, post tension cabling is properly spaced out per plan and 3rd party inspection has been performed, Ufer ground is installed on transformer side of garage. Underground electrical for kitchen island is installed. Okay to pour concrete slab and footings. |