Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Inspection Status: Passed

Inspection History: COT - RSEL - Electrical Underground 

Permit Number - TC-MDP-0524-00685

Inspection Description - COT - RSEL - Electrical Underground 

Inspection Status - Passed

Date Description Inspector Results Comments
08/16/2024 COT - RSEL - Electrical Underground  Passed Concrete forms are set, post tension cabling is evenly spaced, masa clips are evenly spaced and secured to concrete forms, shear wall straps are properly placed to plan requirements and secured to the concrete forms, all underground plumbing pipes are properly wrapped with foam, underground electrical conduit is installed for kitchen island, additional rebar reinforcement is installed per plan, and 20' rebar is properly installed for Ufer ground. Okay to pour concrete for footings and slab.