Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior Clips/Sheathing
Permit Number - TC-MDP-0524-00682
Inspection Description - COT - RSBU - Exterior Clips/Sheathing
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/19/2024 | COT - RSBU - Exterior Clips/Sheathing | Re-inspection required | Missing studs for continuous loads. Add stud to be within the 45* of girder truss. Add cripple studs. Loose shear at kitchen area. Add straps to SGD. Add anchor bolts at garage entry. Nail interior walls per schedule. 8/19/2024 | |
08/23/2024 | COT - RSBU - Exterior Clips/Sheathing | Passed |