Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Roof Nailing 

Permit Number - TC-MDP-0524-00682

Inspection Description - COT - RSBU - Roof Nailing 

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
08/19/2024 COT - RSBU - Roof Nailing  Re-inspection required Missing studs for continuous loads. Add stud to be within the 45* of girder truss. Add cripple studs. Loose shear at kitchen area. Add straps to SGD. Add anchor bolts at garage entry. Nail interior walls per schedule. 8/19/2024
08/23/2024 COT - RSBU - Roof Nailing  Passed