Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Roof Nailing 

Permit Number - TC-MDP-0524-00679

Inspection Description - COT - RSBU - Roof Nailing 

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
08/20/2024 COT - RSBU - Roof Nailing  Re-inspection required Missing 2x underneath beam near stairway. Nail 2x6 stud to exterior in master bathroom. Provide cs16 strap to top plates. Missing king stud at SGD. Nailing pattern second floor bottom plate not per schedule. 8/20/2024
08/22/2024 COT - RSBU - Roof Nailing  Re-inspection required Missing 2x underneath beam near stairway. Nail 2x6 stud to exterior in master bathroom. Provide cs16 strap to top plates. Missing king stud at SGD. Nailing pattern second floor bottom plate not per schedule. 8/20/2024
8/22/24: missing (2)2x4 st 3 1/8" x 12" GLB between foyer and dining room, loose sheathing at master bath upstairs. Bottom plate at second floor not fastened per schedule, GLB at dining room requires (2) cs16x6'.
08/26/2024 COT - RSBU - Roof Nailing  Passed