| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/20/2024 | COT - RSBU - Roof Nailing | Re-inspection required | Missing 2x underneath beam near stairway. Nail 2x6 stud to exterior in master bathroom. Provide cs16 strap to top plates. Missing king stud at SGD. Nailing pattern second floor bottom plate not per schedule. 8/20/2024 | |
| 08/22/2024 | COT - RSBU - Roof Nailing | Re-inspection required | Missing 2x underneath beam near stairway. Nail 2x6 stud to exterior in master bathroom. Provide cs16 strap to top plates. Missing king stud at SGD. Nailing pattern second floor bottom plate not per schedule. 8/20/2024 8/22/24: missing (2)2x4 st 3 1/8" x 12" GLB between foyer and dining room, loose sheathing at master bath upstairs. Bottom plate at second floor not fastened per schedule, GLB at dining room requires (2) cs16x6'. |
|
| 08/26/2024 | COT - RSBU - Roof Nailing | Passed |