Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Roof Nailing
Permit Number - TC-MDP-0524-00679
Inspection Description - COT - RSBU - Roof Nailing
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/20/2024 | COT - RSBU - Roof Nailing | Re-inspection required | Missing 2x underneath beam near stairway. Nail 2x6 stud to exterior in master bathroom. Provide cs16 strap to top plates. Missing king stud at SGD. Nailing pattern second floor bottom plate not per schedule. 8/20/2024 | |
08/22/2024 | COT - RSBU - Roof Nailing | Re-inspection required | Missing 2x underneath beam near stairway. Nail 2x6 stud to exterior in master bathroom. Provide cs16 strap to top plates. Missing king stud at SGD. Nailing pattern second floor bottom plate not per schedule. 8/20/2024 8/22/24: missing (2)2x4 st 3 1/8" x 12" GLB between foyer and dining room, loose sheathing at master bath upstairs. Bottom plate at second floor not fastened per schedule, GLB at dining room requires (2) cs16x6'. |
|
08/26/2024 | COT - RSBU - Roof Nailing | Passed |