Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Roof NailingĀ
| Date |
Description |
Inspector |
Results |
Comments |
| 10/14/2024 |
COT - RSBU - Roof NailingĀ |
|
Re-inspection required |
10/14/24: wrong amount of trimmers at back sliding glass door frame. Anchor bolts at shear wall 9 not to plans. Rsp clip needs nailing at back south east corner. Floor trust at 2nd bearing point in garage need h25 clips. Shear wall 7 second floor bottom plate nailing not to schedule stopped inspection can add more at next inspection |
| 10/21/2024 |
COT - RSBU - Roof NailingĀ |
|
Passed |
10/21/24: All items noted on last inspection have been corrected. Okay to proceed with rough-in of M, P, AND E. |