Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Parcel: 141460410


Addresses:

9620 E HARKES DR


Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Roof Nailing 

Permit Number - TC-MDP-0524-00655

Inspection Description - COT - RSBU - Roof Nailing 

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
10/10/2024 COT - RSBU - Roof Nailing  Re-inspection required Questioning jack truss right of garage above interior bearing wall. Add rsp clips to all 4x from post to bottom plates. Nail all h25 clips at 3 and 4 bearing points and those that are missing nails. Add a35 clips underneath landing. Add shot pins in interior walls. Add anchor bolts per shear wall schedule and those with a leg up from MASA clips. Missing h25 above landing 2nd floor. Interior bottom plates nailing not per schedule. Missing cs16 straps per details north wall. Loose sheathing south wall near bottom plate. Missing bracing on roof trusses. 10/10/2024
10/14/2024 COT - RSBU - Roof Nailing  Passed