Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Roof Nailing
Permit Number - TC-MDP-0524-00655
Inspection Description - COT - RSBU - Roof Nailing
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/10/2024 | COT - RSBU - Roof Nailing | Re-inspection required | Questioning jack truss right of garage above interior bearing wall. Add rsp clips to all 4x from post to bottom plates. Nail all h25 clips at 3 and 4 bearing points and those that are missing nails. Add a35 clips underneath landing. Add shot pins in interior walls. Add anchor bolts per shear wall schedule and those with a leg up from MASA clips. Missing h25 above landing 2nd floor. Interior bottom plates nailing not per schedule. Missing cs16 straps per details north wall. Loose sheathing south wall near bottom plate. Missing bracing on roof trusses. 10/10/2024 | |
10/14/2024 | COT - RSBU - Roof Nailing | Passed |