01/29/2025 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Not Ready | 1/29/25 DWV not under pressure, penetrations at vapor barrier not sealed throughout house and many are touching or very close to touch DWV pipes as well as thermostat lines. Possible leaks when put under test. Nail plate needed at thermostat at floor on second floor. Stopped intermediate. Electrical clearance also not ready. | |