Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
Permit Number - TC-MDP-0524-00634
Inspection Description - COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
Inspection Status - Re-inspection required
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/03/2024 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Re-inspection required | 10/3/24: shear wall missing nailing at front of house. Three point girder at front of house not supported at 2nd bearing point. Issuing anchor bolts at shear walls plans call for 32" on center. Missing lateral bracing at T03SGE trust back of house. T12 trust at back of house webbing is broken needs engineering fix. Jack trust in garage missing h25 clips. Missing rsp clips at south side of home under girder trust. STOPPED INSPECTION more items can be added. | |
| 10/08/2024 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Re-inspection required | 10/8/24: anchor bolt missing at shear wall in great room. Broken Webbing needs engineering fix. | |
| 10/21/2024 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | 10/21/24: All items noted on last inspection have been corrected. Okay to proceed with rough-in of M, P, AND E. |