Inspection Status: Passed
Inspection History: COT - RSBU - Preslab
Permit Number - TC-MDP-0524-00634
Inspection Description - COT - RSBU - Preslab
Inspection Status - Passed
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/05/2024 | COT - RSBU - Preslab | Passed | Concrete forms are set, post tension cabling is properly spaced, additional rebar reinforcement is installed per plan requirements, Ufer ground is in place, masa clips and shear wall hold downs are installed per plan requirements, underground electrical is in place for kitchen island, and all underground plumbing pipes are properly wrapped with foam wrap. Okay to pour concrete. |