Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Roof Nailing
Permit Number - TC-MDP-0524-00634
Inspection Description - COT - RSBU - Roof Nailing
Inspection Status - Re-inspection required
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/03/2024 | COT - RSBU - Roof Nailing | Re-inspection required | 10/3/24: shear wall missing nailing at front of house. Three point girder at front of house not supported at 2nd bearing point. Issuing anchor bolts at shear walls plans call for 32" on center. Missing lateral bracing at T03SGE trust back of house. T12 trust at back of house webbing is broken needs engineering fix. Jack trust in garage missing h25 clips. Missing rsp clips at south side of home under girder trust. STOPPED INSPECTION more items can be added. | |
| 10/21/2024 | COT - RSBU - Roof Nailing | Passed | 10/21/24: All items noted on last inspection have been corrected. Okay to proceed with rough-in of M, P, AND E. |