Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Roof Nailing 

Permit Number - TC-MDP-0524-00630

Inspection Description - COT - RSBU - Roof Nailing 

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
08/09/2024 COT - RSBU - Roof Nailing  Re-inspection required 8/9/24: anchor bolts needed where excessive masa legs are up. Cut nails needed at bottom plates in master bedroom. Studs needed at girder in master bedroom. Stopped inspection more items can be listed at recall.
08/14/2024 COT - RSBU - Roof Nailing  Passed 8/14/24: Red heads have been installed where needed. Added missing studs at master bedroom girder truss. Rough framing for exterior and interior walls is complete. Roof framing and sheathing is properly nailed off with H2.5 clips properly secured to trusses and top plate. Okay to proceed with rough-in work.