Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
| Date |
Description |
Inspector |
Results |
Comments |
| 07/26/2024 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Re-inspection required |
7/26/24: Fire wall shot pins required 24" O.C, Anchor bolt spacing required at 48" O.C, shot pins at interior walls missing throughout, blocking required at firewall at exterior walls, A35 clips required at cross bracing, anchor bolts required 12" from sill plate edge. |
| 08/13/2024 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Canceled |
8/13/24: canceled by contractor |
| 08/15/2024 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Passed |
Ok to stucco exterior walls. |