Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior Clips/Sheathing 

Permit Number - TC-MDP-0524-00604

Inspection Description - COT - RSBU - Exterior Clips/Sheathing 

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
09/09/2024 COT - RSBU - Exterior Clips/Sheathing  Re-inspection required Add strap from beam to header at back patio. SGD missing x2 king studs. Add anchor bolts per shear wall schedule and per every third masa leg upright. Replace header at front entry. (2x10). Add h25's to 3 point bearing trusses. Add rsp clips from bottom plates to post. Missing bracing a truss 3m. 9/9/2024
09/13/2024 COT - RSBU - Exterior Clips/Sheathing  Partial Pass Partial pass. Pending engineer letter of information on the SGD. Okay to proceed to intermediates. 9/13/2024
09/24/2024 COT - RSBU - Exterior Clips/Sheathing  Canceled Canceled per contractor. 9/24/2024
09/27/2024 COT - RSBU - Exterior Clips/Sheathing  Passed Approved. 9/27/2024