Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Parcel: 140363980


Addresses:

6451 S AMBARELLA DR


Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior Clips/Sheathing 

Permit Number - TC-MDP-0524-00588

Inspection Description - COT - RSBU - Exterior Clips/Sheathing 

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
07/16/2024 COT - RSBU - Exterior Clips/Sheathing  Re-inspection required Provide x2 2x6's at entry headers. Loose shear wall at garage. Ledger needs to be up right at great room. Provide nails at ledger in back patio. Correct valley support above hallway. Provide more nails or A35's to gable end trusses. Provide 2x6 framing for plumbing walls. Truss calcs incomplete to verify bracing. 7/16/2024
07/23/2024 COT - RSBU - Exterior Clips/Sheathing  Passed Corrections were made. 7/23/2024