Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Roof Nailing
Permit Number - TC-MDP-0524-00588
Inspection Description - COT - RSBU - Roof Nailing
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/16/2024 | COT - RSBU - Roof Nailing | Re-inspection required | Provide x2 2x6's at entry headers. Loose shear wall at garage. Ledger needs to be up right at great room. Provide nails at ledger in back patio. Correct valley support above hallway. Provide more nails or A35's to gable end trusses. Provide 2x6 framing for plumbing walls. Truss calcs incomplete to verify bracing. 7/16/2024 | |
07/23/2024 | COT - RSBU - Roof Nailing | Passed | Corrections were made. 7/23/2024 |