Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Not Ready
Inspection History: COT - RSBU - Exterior Clips/Sheathing
Permit Number - TC-MDP-0524-00585
Inspection Description - COT - RSBU - Exterior Clips/Sheathing
Inspection Status - Not Ready
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/25/2024 | COT - RSBU - Exterior Clips/Sheathing | Not Ready | ||
06/26/2024 | COT - RSBU - Exterior Clips/Sheathing | Re-inspection required | Loose shear walls at garage. H25 missing at garage and porch area. Missing saddle straps at back patio. Add fire block to dead spaces. Missing anchor bolts. Missing king stud at great room. Add straps to SGD. 6/26/2024 | |
06/28/2024 | COT - RSBU - Exterior Clips/Sheathing | Canceled | Canceled per contractor. 6/28/2024 | |
07/01/2024 | COT - RSBU - Exterior Clips/Sheathing | Re-inspection required (with fee) | Add straps to SGD. Back patio from beams to studs. Missing anchor bolts and shot pins. 7/1/2024 | |
07/03/2024 | COT - RSBU - Exterior Clips/Sheathing | Canceled | Canceled per contractor. 7/3/2024 | |
07/10/2024 | COT - RSBU - Exterior Clips/Sheathing | Passed | corrections were made. 7/10/2024 |