Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Parcel: 140443770


Addresses:

6081 E FALCONRY TR


Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior Clips/Sheathing 

Permit Number - TC-MDP-0524-00573

Inspection Description - COT - RSBU - Exterior Clips/Sheathing 

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
08/30/2024 COT - RSBU - Exterior Clips/Sheathing  Re-inspection required 8/30/24: Anchor bolts missing throughout (6' o.c max), anchor bolts must be within 1/3 of sill plate, anchor bolts must be properly fastened throughout, shear wall nailing not per plan, anchor bolts at shear wall not per plan. STOPPED INSPECTION MORE ITEMS MAY BE ADDED
09/04/2024 COT - RSBU - Exterior Clips/Sheathing  Re-inspection required Not ready. Working in home at intermediate stage. 9/4/2024
09/05/2024 COT - RSBU - Exterior Clips/Sheathing  Passed Approved. 9/5/2024