Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
| Date |
Description |
Inspector |
Results |
Comments |
| 08/30/2024 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Re-inspection required |
8/30/24: Anchor bolts missing throughout (6' o.c max), anchor bolts must be within 1/3 of sill plate, anchor bolts must be properly fastened throughout, shear wall nailing not per plan, anchor bolts at shear wall not per plan. STOPPED INSPECTION MORE ITEMS MAY BE ADDED |
| 09/04/2024 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Re-inspection required |
Not ready. Working in home at intermediate stage. 9/4/2024 |
| 09/05/2024 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Passed |
Approved. 9/5/2024 |