Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Interior Shear Bracing
Permit Number - TC-MDP-0524-00573
Inspection Description - COT - RSBU - Interior Shear Bracing
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/10/2024 | COT - RSBU - Interior Shear Bracing | Re-inspection required | 10/10/24: Shear-walls not fastened per schedule (4"o.c at edges and field required), fasteners at ceilings and walls shall be 3/8" from edge and shall not penetrate more than 1/8", missed stud, at kitchen shear-wall, thermostat shall not be higher then 54" above finish floor, missed stud at bathroom over shower, | |
10/11/2024 | COT - RSBU - Interior Shear Bracing | Passed | Corrections have been made 10/11/24 |