Permit: TC-MDP-0524-00573

Parcel: 140443770


Addresses:

6081 E FALCONRY TR

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Roof Nailing 

Date Description Inspector Results Comments
08/30/2024 COT - RSBU - Roof Nailing  Re-inspection required 8/30/24: Anchor bolts missing throughout (6' o.c max), anchor bolts must be within 1/3 of sill plate, anchor bolts must be properly fastened throughout, shear wall nailing not per plan, anchor bolts at shear wall not per plan. STOPPED INSPECTION MORE ITEMS MAY BE ADDED
09/04/2024 COT - RSBU - Roof Nailing  Re-inspection required Not ready. Working in home at intermediate stage. 9/4/2024
09/05/2024 COT - RSBU - Roof Nailing  Passed Approved. 9/5/2024