Inspection Status: Canceled

Inspection History: RSBU - Building Progress

Permit Number - TC-MDP-0524-00553

Inspection Description - RSBU - Building Progress

Inspection Status - Canceled

Date Description Inspector Results Comments
11/01/2024 RSBU - Building Progress Canceled
11/12/2024 RSBU - Building Progress Re-inspection required Missing fha plate at kitchen island, missing bracing for 4 gang box at dining area, missing fire foam at dining area, shower not under test. Stopped inspection-additional items may be added.
11/13/2024 RSBU - Building Progress Re-inspection required 11/13/24. FAIL. Improper blocking at four gang light switch. Use a 2 x 6 on its side. Missing light switch or receptacle at primary bathroom. Missing H2 five clips at Bering wall between bedroom and dining room. Another failed inspection will result in a reinspection fee.
11/15/2024 RSBU - Building Progress Not Ready 11-15-24, not ready. schedule at finals.